Installing and configuring the Honeywell/HandHeld 7850 and 7600 series mobile devices is quick and easy.
- .NET Compact Framework –
Windows Mobile 6 versions have .NET CF 2.0 already installed, but the installer will try to install it anyway. You may simply cancel the installation of .NET CF 2.0.
- SqlCE –
After SqlCE is installed, you will probably asked to reboot your device. Please
do so and wait until the device reconnects before continuing.
- Configure Scanner –
Check the scanner configuration by going to Start > Power Tools > EZConfig Utilities > ScanWedge. When the ScanWedge applet comes up, go to Scanwedge > Settings as shown:
Check the following settings:
-
Ensure that PrefixKeys is enabled and its value is 12.
-
Ensure that SuffixKeys is enabled and its value is 13.
-
Ensure that SendMode is enabled and its value is Virtual Keys.
Next, click VKMapping and add insert a new key for 12, as shown, if not already present:
- Launch Scanner – Lanch the ScanWedge scanner applet by going to Start > Power Tools > ScanWedge. Note, you will need to restart the ScanWedge application anytime you make a change to the ScanWedge settings.
- Symbology Specific Settings –
Depending on your labels, you may also need to check the settings for individual symbologies. From the ScanWedge setings, click Sybologies.
- Retail Mobile Suite Settings –
On your device, go to Device Configuration > Wedge. Click
Reset. Scan a barcode. This step
trains Retail Mobile Suite as to which buttons on the device initiate scans.
|
 |
 |